Solution Electrical Numerical 4
Numerical 4: The
low-voltage release of an a.c. motor-starter consists of a solenoid into
which an iron plunger is drawn against a spring. The resistance of the
solenoid is 35 ohm. When connected to a 220 V, 50 Hz, a.c. supply the
current taken is at first 2A, and when the plunger is drawn into the
“full-in” position the current falls to 0.7 A.
Calculate the inductance of the solenoid for both positions of the
plunger, and the maximum value of flux- linkages in weber-turns for the
“full-in” position of the plunger.
Solution: Given: Resistance of solenoid (R) = 35 Ω
Voltage = 220 V
Frequency (f) = 50 Hz
Initial Current $\displaystyle \mathrm{I_1}$ = 2 A
Final Current $\displaystyle \mathrm{I_2}$ = 0.7 A
When Plunger out:
Impedance $\displaystyle \mathrm{(Z) = \frac{V}{I} = \frac{220}{2} = 110}$ Ω
and R = 35 Ω
$\displaystyle \mathrm{X = \sqrt{Z^2-R^2}\ =\ \sqrt{110^2-35^2}\ =\ 104.28 }$ Ω
But, $\displaystyle \mathrm{X =2\pi fL }$
$\displaystyle \mathrm{104.28 =2\pi 50L }$
∴ L = 0.332 H
When Plunger In:
Impedance $\displaystyle \mathrm{(Z) = \frac{V}{I} = \frac{220}{0.7} = 314.28}$ Ω
and R = 35 Ω
$\displaystyle \mathrm{X = \sqrt{Z^2-R^2}\ =\ \sqrt{314.28^2-35^2}\ =\ 312.3 }$ Ω
But, $\displaystyle \mathrm{X =2\pi fL }$
$\displaystyle \mathrm{312.3 =2\pi 50L }$
∴ L = 0.995 H
We know that
$\displaystyle \mathrm{L = \frac{N\phi }{I} }$
Here Nф = Flux linkage
thus, Flux linkage = L x I = 0.995 x √2 x 0.7 = 0.985 w-turn.
Comments
Post a Comment